GSE 460/465 Indicator
Designed
to outperform and outlast all comparable indicators, the Model
460 and 465 offer unparalleled performance and value. Equipped
with the industries most sophisticated parameter map and programmable
features, the 450 series indicators deliver easy to use operation
with the flexibility to meet your application requirements now
and in the future.
Features
-
Macros
- 15 programmable macros, applies the principles
of boolean logic in a sequential structure, provides a method
of performing repetitive keystrokes and operations, simplifies
indicator use by automating indicator operation
-
Database
- 15 programmable databases are used to manage
critical application data, this powerful feature stores weight
information and other user defined Data Registers such as
part numbers, formulas, etc., 18 functions include store,
recall, sort, upload
-
Data Registers
- 15 programmable data registers can be defined
as an integer, unsigned integer, float or string, common data
registers include part number, lot #, Operator ID, commodity
code, etc.
-
Communications
- a facotry default transmission will send:
Gross, net and tare weights. Using the Custom Transmit Tables,
other transmissions may be programmed to send weight data,
Data Registers or ASCII control codes for application specific
labels, reports, etc.
-
Input
Interpreter Tables are programmed
to recieve RS232 serial data and perform a specific task,
ie. a bar code scanner scans a formula #, the data is received
into an input interpreter table and invokes a macro that recalls
target weights.
-
Enclosure
- NEMA 4X (IP66), stainless steel, also available
in panel mount
-
Display
- bright 6 digit .75" (20.3mm) Vaccum
Fluorescent (VFD) with 2.5 (10 character) dot matrix for scale
status and operator prompting
APPLICATIONS
|
| Performance |
| Resolution |
100,000d
(+/-500,000 internal) |
| A/D
Conversion |
60
Hz |
| Flash
Memory |
1M
Bytes |
| Calibration |
Selectable,
5 point linearization or enter L.C. mV/V F.S. |
| A/D
Filterin |
GSE
FIR (Finite Input Response) Filter with selectable display update
rate |
| Units
of Measure |
4
user defined per scale |
| Custom
Units |
2
user defined per scale (ie. Tons) |
| Zero
Adjustment |
Selectable,
0.01 - 100% F.S. |
| Span
Adjustment |
0.1
- 20mV/V |
| Non-Linearity |
0.005%FS,
L.C. Dependent |
| Operating
Temp |
-10oC
-+40oC |
| Excitation
Power |
12
-350 ohm bridges |
| Input
Signal Connect |
4
or 6 conductors with sense leads |
| Excitation
Current |
350
mA, short circuit protected |
| Excitation
Voltage |
10VDC
short circuit protected |
| Time/Date
Clock |
Volatile,
battery backed optional |
| Warranty |
2
Year limited |
| Electrical |
| Power
Input |
AC,
90 - 250VAC, 50/60Hz |
| Fuse |
0.5A
Slo-Blow (when using AC power) |
| Setpoint
I/O |
| I/O
Scan Rate |
16ms
maximum |
| Number
of I/O |
8
physical I/O maximum, optional 16 tOTAL (8 physical, 8 logical) |
| Output
Voltage Rating |
20
- 240 VAC 1A
30 - 60 VDC 2A |
| Input
Voltage Rating |
60
- 135 VAC
200 - 250 VAC
3 - 30 VDC |
| I/O
Timer Resolution |
10ms |
| Remote
Contact Input |
2
total for TARE, PRINT, START, STOP, etc.
Invokes macros 6 & 7 if programmed |
| Communications |
| Port
1 |
RS232
Full Duplex or Optional RS485 Multi-drop
Optional 20mA Current Loop |
| Port
2 |
RS232
Full Duplex, no RTS on COMM 2 |
| Protocols |
ModbusTM(DeviceNetTM,
Profibus, opt.) DeviceNetTM up to 500k Baud ODVA Approved.
Profibus up to 12M Baud PTO Approved. DeviceNetTM and
Profibus mount in SBM slot and use COMM 1 |
| Baud
Rates |
150
- 58,300 bps |
| Custom
Transmit Tables |
4
- user defined RS232 output tables |
| Input
Interpreter Tables |
15
- user defined RS232 input tables |
| Options
and Accessories |
| Multi-Scale
Module |
allows
for simultaneous monitoring of an additional signal input |
| Analog
Output Module |
isolated
16-bit signal output, 0-10VDC, 0-20mA or 4-20mA, software adj. zero/gain
(2 analog modules max) |
| I/O
Relay Module |
8
Variations of Quad I/O boards. (AC & DC - 4 Output, 4 Input
or 2 In/2 Out) only one option mounts inside the enclosure. |
| RS485
Module |
isolated
serial communication module replaces RS232 on Port 1, multi-drop
wit 251 devices max, half or full duplex up to 4000 feet, 56K bps
max |
| 20mA
Current Loop |
isolated
serial communication module replaces R232 on Port 1, TX- Active
or Passive, RX-Passive, 9600 bps max, 12 VDC, 1000 foot loop |
| Alpha
Keyboard |
allows
alpha character entry into data registers such as Product Name,
Part Number, etc. |
| Dura-Shild |
0.020"
layer of weatherable lexan film with adhesive backing, applies to
the front of the indicator, keeps display and keyboard clean in
extreme environments |
| GSE
ReFlash Software |
download
firmware enhancements via RS232 port |
| BDM
Flash Software |
download
firmware enhancements via BDM port |
| DiveceNettm |
allows
the indicator to be a slave divece on the network - ODVA approved |
| Profibus |
DP
allows the indicator to be a slave device on the network - PTO approved |
| GSE
M460/465 Indicator |
|
Model |
Keypad |
Size |
Weight |
| M460 |
100,000d
(+/-500,000 internatl) |
11.01"
W x 7.24" H |
6.5
lb |
| M465 |
100,000d
(+/-500,000 internatl) |
11.01"
W x
8.96" H |
7
lb |

Call TOLL FREE 800-394-6622 for more information
and prices
Back
to Top
|