GSE 560/562 Indicator
The Model
560 and 562 offers unparalleled performance in a mid range weight
indicator. Equipped with a comprehensive parameter map, programmable
features and a multitude of option mudules, the 560 series is
the indicator of choice for applications that require value, quality
and performance.
Features
-
Macros
- 100 programmable macros, applies the principles
of boolean logic in a sequential structure, provides a method
of performing repetitive keystrokes and operations, simplifies
indicator use by automating indicator operation
-
Database
- 100 programmable databases are used to manage
critical application data, this powerful feature stores weight
information and other user defined Data Registers such as
part numbers, formulas, etc., 18 functions include store,
recall, sort, upload, etc.
-
Data Registers
- 100 programmable data registers can be defined
as an integer, unsigned integer, float or string, common data
registers include part number, lot #, Operator ID, commodity
code, etc.
-
Communications
- a facotry default transmission will send:
Gross, Net and Tare weights. Using the Custom Transmit Tables,
other transmissions may be programmed to send weight data,
Data Registers or ASCII control codes for application specific
labels, reports, etc.
-
Input
Interpreter Tables are programmed
to recieve RS232 serial data and perform a specific task,
ie. a bar code scanner scans a formula #, the data is received
into an input interpreter table and invokes a macro that recalls
target weights.
-
Enclosure
- NEMA 4X (IP66), stainless steel with swivel
bracket or panel mount
-
Remote
Display - allows indicators to operate
as a remote display (slave device)
APPLICATIONS
|
Performance |
| Full
Scale (F.S.) |
Selectable
0 to 999,990 |
| A/D
Conversion |
60
Hz |
| Resolution |
100,000d
(+/-500,000 internal) |
| Flash
memory |
1M
Bytes |
| Calibration |
Selectable,
5 point linearization or enter Load Cell mV/V full scale |
| A/D
Filtering |
GSE
Fir (Finite Input Response) filter with selectable display update
rate |
| Units
of Measure |
4
user selectable per scale |
| Custom
Units |
2
user defined per scale |
| Zero
Adjustment |
Selectable,
0.01 - 100% F.S. |
| Span
Adjustment |
0.1
- 20 mV/V |
| Non
- Linearity |
0.005%
F.S., L.C. dependent |
| Operating
Temp |
-10oC
to +40oC |
| Excitation
Power |
14
- 350 ohm bridges |
| Input
Signal Connect |
4
or 6 conductors with sense leads |
| Excitation
Current |
400 mA, short circuit protected |
| Excitation
Voltage |
10
VDC, short circuit protected |
| Time/Date
Clock |
Non-volatile,
battery backed |
| Database
Memory |
4K
standard, expandable to 8K or 156K |
| Warranty |
2
year limited |
Electrical |
| Power
Requirement |
AC,
90-250 VAC, 50/60 Hz; DC, 10-32 VDC |
| Fuse |
0.8A
Slow - Blow (when using AC power) |
Setpoint
I/O |
| I/O
Scan Rate |
16ms
maximum |
| Number
of I/O |
48
total (32 physical - optional, 16 logical - software) |
| Remote
Contact Input |
2
total for TARE, PRINT, START, STOP, etc. Invokes macros 6 &
7 if programmed |
Communications |
| Port
1 |
RS232
Full Duplex, RS485 or 20 mA optional |
| Port
2,3 |
RS232
Full Duplex, no RTS on Comm 3 |
| Protocols |
ModbusTM
RTU, ASCII, Device Net (optional) Profibus (optional) |
| Custom
Transmit Tables |
100
- user defined RS232 output tables |
| Input
Interpreter Tables |
100
- user defined RS232 input tables |
| Baud
Rate |
150-58,300
bps |
Physical |
| Keypad |
22
Key, durable elastomeric rubber |
| Standard
Size |
11.01"
W (27.98 cm) x 8.96" H (22.76 cm) |
| Weight |
7lb
(3.18kg) |
| Panel
Mount Cutout |
9.00/9.25"
W (22.86/23.5 cm) x 8.00/8.25" H (20.32/20.96 cm) |
Options
and Accessories |
Note:
2 serial bus module [SBM] and 1 communication module mount internat
to the enclosure. |
| Multi-Scale
Module[SBM] |
Up
to 3 additional signal inputs (simultaneously monitored) |
| Analog
Output Module[SBM] |
isolated
16-bit signal output, 0-10 VDC, 0-20 mA or 4-20 mA, software adjust
zero/gain (4 analog modules max) |
| I/O
Relay Module |
8
variations of Quad I/O boards[SBM] or 16 position I/O boards |
| RS485
Module |
Replaces
comm port 1, Isolated multi-drop with 251 devices max, half or full
duplex up to 4000 feet, 56K bps max |
| 20
mA Current Loop |
Replaces
comm port 1, Isolated TX-Active or Passive, RX-Passive, 9600 bps
max, 12 VDC, 1000 foot loop |
| Device
Net Module |
ODVA
approved Interface module for fieldbus networking, [SBM] footprint
mounting |
| Profibus |
PTO
approved interface module for fieldbus networking, [SBM] footprint
mounting |
| Database
Module |
256K
Ram, battery backes. Store critical application data |
| Alpha
Keyboard |
Allows
alpha character entry. Uses standard keyboard with GSE SCK adapter |
| ReFlash
software |
download
firmware enhancements and updates |
| Dura-Shild |
Weatherable
lexan film covers keypad and display for extreme environments |
| GSE
M560/562 Indicator |
|
Model |
Resolution |
Display
|
Units
of Measure |
Size |
Weight |
| M560 |
100,000d
(+/-500,000 internatl) |
VFD,
7 segment, 0.75"
6 digit weight display with 2x5 VFD scale status and operator prompting
display |
4
user defined per scale |
11.01"
W x 8.96" H |
7
lb |
| M562 |
100,000d
(+/-500,000 internatl) |
LCD,
8 line x 40 character graphic display, backlight, 3 font sizes |
4
user defined per scale |
11.01"
W x
8.96" H |
7
lb |

Call TOLL FREE 800-394-6622 for more information
and prices
Back